420
Selecting a destination selection button for 
a snapshot
You can set whether snapshots are recalled for each 
destination selection button.
1
In the Engineering Setup >Panel >Aux Assign >RTR 
Mode Setting menu (7323.1), select the target 
destination button number to set.
2
Press [SS Enable] to enable/disable the function.
To enable, press [SS Enable], turning it on. When a 
snapshot of the router is recalled, the destination 
selection buttons set the destination for the recall.
When a destination selection button is set to Inhibit, 
the destination snapshot is not recalled.
Settings Relating to 
Button Assignment
The following functions can be assigned to the user 
preference buttons on the menu panel, the memory recall 
buttons on the utility/shotbox control block, and the cross-
point buttons on the cross-point control block (utility/
shotbox mode).
• Menu shortcut
• Utility command
• Macro register
• Shotbox register
Assigning Functions to User 
Preference Buttons
1
In the Engineering Setup >Panel >Prefs/Utility menu 
(7324), select the target button to set.
2
In the <Action> group, select the function to assign.
Menu Shortcut: Assign a frequently used menu to be 
recalled (menu shortcut).
Utility Command: Assign a function setting (utility 
command).
Macro Recall: Assign a macro register recall.
Shotbox Recall: Assign a shotbox register recall.
3
Perform the following operations, according to the 
selection in step 2.
When [Menu Shortcut] is selected: When the user 
preference button on the menu panel is blinking, 
display the shortcut menu. Press the target user 
preference button to set to assign a menu shortcut. 
When finished, press [Menu Shortcut] again.
When [Utility Command] is selected: Select a 
command to assign in the list on the right side of 
the status area.
a) For “DCU GPI Test Fire” only
When [Macro Recall] is selected: Select a macro 
register to assign in the list on the right side of the 
status area.
Note
No. Parameter Adjustment
3 Command Utility command selection
4
 a)
GPI No GPI number
No. Parameter Adjustment
3 Macro Macro register selection