SOYAL
ACCESS CONTROL SYSTEM
®
AR-725-E
V220916
- 9 -
Command List
Function Command Exposition
Entering programming mode PPPPPP PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
Exiting programming mode and enabling all device
into arming status.
Including AR-725-E, WG Reader
Enabling each device into arming status. U U
Enable target unit
(
0=AR-725-E
,
1=WG Reader
)
Node ID setting 00 NNN MMM AAA
NNNNode ID,(001~254)
MMM
AR-725-E
Door Number,(001~255)
AAAWG
Reader
Door Number,(001~255)
IP Address assign (Must power reset)
01 0 CCCCCCCCCCCC
default value =
192 .16 8.1.127
CCCCCCCCCCCC = 192168001127
If set to 000.000.000.000 will enable DHCP otherwise
will disable DHCP
01 1 255255255000
Netmask
01 2 192168001254
Gateway assign
Door relay time setting 02 U TTT
UEnable target unit (0=
AR-725-E
, 1=WG Reader)
TTTDoor relay time000 (Output constantly)
001~6001-600 Sec.601~6090.1~0.9Sec.
Alarm relay time setting 03 TTT
TTT
Alarm relay time
000 (Output constantly)
001~600
1~600
Sec.
Mode setting 04 M M
4 (Mode 4)
M
8 (Mode 8)
Arming delay time setting
05 TTT Base on second, range: 001~255
Alarm delay time setting 06 TTT Base on second, range: 001~255
Master card setting 07 SSSSS EEEEE
SSSSS-EEEEE
00000~15999
SSSSS= starting user address; EEEEE= ending user address
Auto-open zone setting
08
MW
NN
HHMMhhmm
7123456H
M=
AR-725-E
; W=WG Reader (
0=disable; 1=enable
)
NN
16 sets of auto-open zone (Range: 00~15)
HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Master code settings 09 PPPPPPRRRRRR
PPPPPP= New master code
RRRRRR= Repeat the new master code
Suspend or delete tags
Suspend
10 SSSSS EEEEE
:Suspend :Delete
SSSSS= starting user address; EEEEE= ending user address
Delete
10 SSSSS EEEEE
Recover tag 11 SSSSS EEEEE
SSSSS= starting user address; EEEEE= ending user address
Setting up Card or PIN mode by user addressModify the
user's access PIN according to the user's address, and
change the control mode to "Card or PIN"
12 UUUUU PPPP~PPPPPPPP
UUUUU= user address;
PPPP~PPPPPPPP=4digit (default)~8-digit individual PWD
(Access mode: Card or PIN)
Setting up Card and PIN mode by user address 13 UUUUU PPPP~PPPPPPPP
Arming output setting 14 TTT
Base on 1ms, range:1~255, default value=10,
Input 0= Timeless
Duress code setting 15 PPPP
PPPP4-digit PWD (0001-9999) ; Default value0000
The Duress Code 0000 means that disable Duress Function
and the default value is set as 0000 already.
Card number modication 16 UUUUU SSSSSCCCCCC
UUUUUuser address
SSSSS5 digit site code
;
CCCCC5 digit card code
Arming PWD setting 17 PPPP
PPPP
4-digit PWD (0001-9999)
Default value
1234
Enabling or Disabling into arming status
Card+
NNNN
NNNN
Arming PWD
UEnable target unit (0=AR-725-E , 1=WG Reader)
Enabling or Disabling each device into arming status.
Card+
NNNN U
Enabling all device into arming status.
Card+
NNNN
Disabling
all device into arming status.
Card+
NNNN
Door open waiting time 18 U TTT
U
Enable target unit
(
0=AR-725-E
,
1=WG Reader
)
TTT=Door open waiting time:001~600;default value:15 sec.
Add card by presenting 19 UUUUU QQQQQ
UUUUUuser address
QQQQQ=Card quantity(00001=Continuously inducting)
Reader additional setting 20 0 or 1 ???
UEnable target unit
(0=
Main Controller Parameter Setting
,
1=WG Input Port Parameter Setting)
???=Function default value