26
CURRENT SENSING
Check position of selection switch.
Interior light failed. Check bulbs.
Current sensing not working Increase trigger sensitivity by
when interior light illuminated relocating RED wire to an alternative
12V supply further from the battery in
the fuse box.
INDICATOR OUTPUT
When the alarm is activated Wiring fault or fuse blown in harness
indicators do not flash. Check wiring and replace any blown
fuses.
STARTER INHIBIT NOT WORKING
When PINK wire is connected to a 12V ignition controlled supply in the START and
RUN position of the ignition switch.
CAR WILL NOT START
Check the connections to the ORANGE and BROWN immobiliser wires.
If none of the a bove solutions solve the problem either consult your dealer, or contact
the Sparkrite Technical and After Sales Service ( T.A.S.S.) o n 01429 862616