SpectraGmbH&Co.KG
vertrieb@spectra.de
UserManual
SpectraPowerBox 410Series
Version1.2
May2020
92
6.1 PB-400-COM Module Connector Definition & Settings
COM5 / COM6: RS232 / RS422 / RS485 Connector
Connector Type: 9-pin D-Sub
COM5 / COM6
DB9
Pin
RS232
Definition
RS422 / 485
Full Duplex
Definition
RS485
Half Duplex
Definition
1 DCD TX- DATA-
2 RXD TX+ DATA+
3TXDRX+
4DTRRX-
5GND
6DSR
7RTS
8CTS
9RI
COM5/6 Voltage Function Setting : Pin Define SW2 Switch
Location Function DIP1 DIP2
SW2 on
CMI-COM
Module
COM5
0V(RI) ON (Default) ON (Default)
5V ON OFF
12V OFF OFF
Location Function DIP3 DIP4
SW2 on
CMI-COM
Module
COM6
0V(RI) ON (Default) ON (Default)
5V ON OFF
12V OFF OFF
ON
OFF
ON
OFF
ModelNo. Description
PB‐400‐COM
CMIModulewith2xRS232/422/485(Support5V/12V)/1xUniversal
Bracketwith2xDB9CutoutforPowerBox 400/410Series