IM-P403-88 AB Issue 5
39
10. Technical information
10.1 For technical assistance
Contact your local Spirax Sarco representative. Details can be found on order / delivery
documentation or on our web site: www.spiraxsarco.com
10.2 Returning faulty equipment
Please return all items to your local Spirax Sarco representative. Please ensure all items
are suitably packed for transit (preferably in the original cartons).
Please provide the following information with any equipment being returned:
1. Your name, company name, address and telephone number, order number and invoice
and return delivery address.
2. Description and serial number of equipment being returned.
3. Full description of the fault or repair required.
4. If the equipment is being returned under warranty, please indicate:
- Date of purchase.
- Original order number.
10.3 Power supply
Mains voltage range 110 V to 240 Vac at 50 / 60 Hz
Power consumption 7.5 W (maximum)
10.4 Environmental
General Indoor use only
Maximum altitude 2 000 m (6 562 ft) above sea level
Ambient temperature limits 0 - 55°C (32 - 131°F)
Maximum relative humidity
80% up to 31°C (88°F) decreasing
linearly to 50% at 40°C (104°F)
Overvoltage category III
2 (as supplied)
Pollution degree
3 (when installed in an enclosure) - Minimum of IP54
Enclosure rating (front panel only) IP65 (verified by Trac Global)
Torque rating for panel screws 1 - 1.2 Nm
LVD (safety) Electrical safety EN 61010-1
EMC Immunity / Emission Suitable for heavy industrial locations
Enclosure Material Polycarbonate
Front panel Material Silicone rubber, 60 shore.
Solder Tin / lead (60 / 40%)