Table 1
The 'T' bracket can be moved towards the right or towards the left. This allows the adjustment
as displayed below between the lever fulcrum and the pin:
Actuator stroke (mm)
Distance between feedback
lever fulcrum and pin
Feedback lever
20 70
30 70
50 80
70 80
75 115
100 115
Step 3
Attach the bracket to the actuator with the screw M8 x 20 with washers (Figure 8).
Take care to insert the feedback pin in the slot of the feedback lever while you attach the
positioner (Figure 9).