ASP 116 EVOLUTION INSTALLATION MANUAL
Sprinte SAS. All rights reserved , including translations.
13
Choose « YES » . Do not change
Choose « 10 ms » . Do not change
+
Set the motor’s type
For a « GEARLESS SPRINTE » only:
Set the Gearless SPRINTE’s type
Set the lift’s reeving
Choose « SYNC.BF» . Do not change
Set the Motor’s plate speed
Set the Motor’s plate nominal current
FILTER
YES
FILTER VALUE
10 ms
FREQ. INVERTER
MOTOR DATA
GEARLESS TYPE
103 02.1/4.6KW
RATED SPEED
167 rev/mn
RATED SPEED
XXXX tr/min
REEVING
1 :1
MACHINE TYPE
STANDARD
MACHINE TYPE
xxxxxxxx
CONTROL TYPE
SYNC. CL
RATED CURRENT
10,0 A
RATED CURRENT
XX,x A