ASP 116 EVOLUTION INSTALLATION MANUAL
Sprinte SAS. All rights reserved , including translations.
14
See tables below according to the inverter model.
See tables below according to the inverter model.
Choose « ABC »
Set the Motor’s plate nominal torque
Set the Motor’s plate poles pairs number
Some motor’s plates indicate the poles number.
400V Inverter
Thermal current
limitation
230Vac Inverter
Thermal current
limitation
ATVLIFT 10A
14,2A
ATVLIFT 27A
37,4A
ATVLIFT 14A
19,4A
ATVLIFT 33A
44,8A
ATVLIFT 17A
23,4A
ATVLIFT 27A
37,6A
ATVLIFT 33A
44,8A
ATVLIFT 48A
65A
ATVLIFT 37kW
107,4A
PHASE ROTATION
ABC
MOTOR TORQUE
670 Nm
MOTOR TORQUE
xxx Nm
THERM.CURRENT
15,0 A
RATED CURRENT
XX,x A
CURRENT LIMIT.
15,0 A
CURRENT LIMIT.
XX,x A
POLE PAIRS
12
POLE PAIRS
xx
-
-
-
-
-