Installation Waukesha Cherry-Burrell
®
Brand C-Series Pump
01/2019 95-03008-IEC Page 15
Electrical Connections
DANGER
The pump contains internal moving parts. DO NOT put hands or
fingers into the pump body ports or drive area at any time during
operation. To avoid serious injury, DO NOT install, clean, service,
or repair the pump unless all power is off and locked out and the
pump is de-pressurized.
CAUTION
The motor must be installed by qualified personnel, e.g., a
licensed electrician.
Read the motor manufacturer's instructions before making an
installation. Follow the manufacturer's lubrication schedules.
Check the motor nameplate to be sure that the motor is
comp
atible with the electrical supply and all wiring, switches,
and starters. Make sure all overload protections are correctly
sized.
Check the pump rotation following an electrical installation.
T
he correct direction of rotation is counterclockwise when
facing the pump inlet connection. See Figure 4 on page 13
and label 33-34 in Figure 8.
Before First Startup
Clean Pump and Piping
Disassemble the pump and clean all product contact parts and
seal parts prior to first operation. Follow instructions in the
“Cleaning Safety Procedures” on page 15 and “Pump Disassem-
bly - Pin Impeller Design” on page 20 or “Pump Disassembly -
Sealed Impeller Design” on page 32. Thoroughly clean the pump
of any materials that co
uld have accumulated during installation.
Cleaning Safety
Procedures
Manual Cleaning
Do not use toxic and/or flammable solvents.
Lock out electrical power and shut off all air prior to cleaning
th
e equipment.
Keep electrical panel covers closed and power off when
washin
g the equipment.
Clean up spills as soon as possible.
Never attempt to clean the equip
ment while it is operating.
Wear proper protective clothing.
Cleaning-In-Place (CIP)
1. Make certain that all connections in the cleaning circuit are
properly applied and tightened to avoid contact with hot water
or cleaning solutions.
2. When the cleaning cycle is controlled from a remote or auto-
mated cleaning center, establish safe procedures to avoid
automat
ic start-up while servicing equipment in the circuit.
Label part numbers:
121694+: Warning-Read Manual
33-34: Direction of Rotation
33-33: Warning-Rotating Shaft
33-63: Warning-Keep Fingers Out
125096+: 3-A Label
Figure 8 - Replaceable Label Location
125096+
33-63
33-33
33-34
121694+
CT100-627
DANGER
To prevent an accidental start-up, lock
out the power source using your lock and
key.