EasyManua.ls Logo

SPXFLOW C Series - Type “E” Water-Cooled Balanced Double Seal Option

SPXFLOW C Series
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Waukesha Cherry-Burrell
®
Brand C-Series Pump
Page 52 95-03008-IEC 01/2019
Type “E” Water-Cooled
Balanced Double Seal
The Type “E” seal consists of two carbon seals inside a stuffing
box that is attached to the backplate. Its sealing action is the
same as the external balanced seal. This seal design is used in
applications where a vacuum-tight, cool operating seal is
required.
NOTE: The
C-100 is not available with
“DG”, “E” or “F” seals.
Periodically inspect all parts of the pump to prevent malfunctions
caused by worn or broken parts.
Seal Servicing
1. Disconnect the water inlet and outlet from the stuffing box.
2. With a wrench of appropriate size, remove the guard assem-
bly.
NOTE: Disa
ssembly for repair is the
same procedure as for cleaning.
3. Remove the casing and clamp assembly.
4. Remove the four screws (17A) that retain the stationary gland
r
ing (17) to the stuffing box.
5. Slide the stuffing box and backplate assembly forward off the
st
ub shaft.
6. Remove the inboard rotary seal (80), seal O-ring (80B), cup
(
80G), and seal spring (80H) from the shaft.
7. Loosen the two setscr
ews and remove the drive collar (80J).
8. Remove the remaining inboard rotary seal, seal O-ring, cup,
an
d stationary gland ring from the shaft.
Items in Figure 124 and Figure 125:
11B
17
17A
17B
17C
80
80B
80G
80H
80J
83C
J
Backplate
Stationary Gland Ring
Screws (4)
O-ring
lock washer
Inboard Rotary Seal
O-ring
Cup
Spring
Drive Collar
Stuffing Box
Stuffing Box and Backplate
NOTE: A larger exploded view of the
“E” Seal with parts list is on page 73.
DANGER
The pump contains internal moving
parts. DO NOT put hands or fingers
into the pump body ports or drive area
at any time during operation. To avoid
serious injury, DO NOT install, clean,
service, or repair pump unless all
power is off and locked out and the
pump is de-pressurized.
DANGER
To avoid serious injury, shut off and
drain product from the pump prior to
disconnecting the piping.
NOTE: Take care to protect the
sealing face and edges of the
backplate from nicks and scratches.
Figure 124 - Parts Stack for Stuffing Box
Figure 125 - “E” Seal Exploded View
11B
83E
83C
83F
83D
80
80B
80G
80H
80M
80J
80G
80B
80
17B
17
17C
17A
CT100-058