Priming the Pump
Priming the Pump with the Feed Source Above
Pump Level
1. Fill the supply tank with liquid and open the supply line (suc-
tion) valve (see Figure 9, item A).
2. Open the discharge valve to vent any air trapped in the sup-
ply line or casing (see Figure 9, item C).
3. Resume the “Starting the Pump” procedure on page 17, at
step 3.
Priming the Pump with the Feed Source Below
Pump Level
The pump will not self-prime if the liquid supply is below the pump
level. If the liquid supply is below the pump level, provide an out-
side source for priming.
1. Close the discharge valve (see Figure 10, item C) and open
the air vents.
2. Open the valve in the outside supply line (see Figure 10, item
A) until liquid flows from the vent valves.
3. Close the vent valves.
4. Close the outside supply line.
NOTE: U
se a type of check valve system (see Figure 10, item B)
to keep the supply line and pump casing flooded with liquid;
oth
erwise the pump must be primed before each operation.
5. Resume the “Starting the Pump” procedure on page 17, at
step 3.
Stopping the Pump
T
1. To stop the pump, shut off power to the pump motor.
NOTE: Liqu
id in the system can flow freely through the pump; the
pump does not act as a shutoff valve.
2. Shut off the supply and discharge lines.
Figure 9 - Pump Below Supply
(Feed Source Above Pump Level)
Figure 10 - Pump Above Supply
(Feed Source Below Pump Level)
DANGER
The pump contains internal moving parts. DO NOT put hands or
fingers into the pump body ports or drive area at any time during
operation. To avoid serious injury, DO NOT install, clean, service,
or repair the pump unless all power is off and locked out and the
pump is de-pressurized.
CAUTION
The motor must be installed by qualified
personnel, e.g., a licensed electrician.