19Lever Blade Installation
Press the bladder into the reservoir cap, make sure the bladder is
properly seated into the reservoir cap. The bladder should be flush
with the cap.
Insert the reservoir cap/bladder assembly onto the lever body.
Use a torque wrench with a T10 TORX® bit to tighten each
reservoir cap bolt to 2.7-3.2 N·m (24-28 in-lb).
Spray isopropyl alcohol on the lever body and clean it with a rag.
10
11
12
T10 TORX® 2.7-3.2 N•m (24-28 in-lb) T10 TORX®
13