High-resolution timer (HRTIM) RM0440
1070/2126 RM0440 Rev 4
27.5.80 HRTIM fault input register 3 (HRTIM_FLTINR3)
Address offset: 0x408
Reset value: 0x0000 0000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
FLT4
RSTM
FLT4
CRES
FLT4CNT[3:0]
FLT4
BLKS
FLT4
BLKE
FLT3
RSTM
FLT3
CRES
FLT3CNT[3:0]
FLT3
BLKS
FLT3
BLKE
rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw
1514131211109876543210
FLT2
RSTM
FLT2
CRES
FLT2CNT[3:0]
FLT2
BLKS
FLT2
BLKE
FLT1
RSTM
FLT1
CRES
FLT1CNT[3:0]
FLT1
BLKS
FLT1
BLKE
rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw
Bit 31 FLT4RSTM: Fault 4 reset mode
Refer to FLT5RSTM description.
Bit 30 FLT4CRES: Fault 4 counter reset
Refer to FLT5CRES description.
Bits 29:26 FLT4CNT[3:0]: Fault 4 counter
Refer to FLT5CNT description.
Bit 25 FLT4BLKS: Fault 4 blanking source
Refer to FLT5BLKS description.
Bit 24 FLT4BLKE: Fault 4 blanking enable
Refer to FLT5BLKE description.
Bit 23 FLT3RSTM: Fault 3 reset mode
Refer to FLT5RSTM description.
Bit 22 FLT3CRES: Fault 3 counter reset
Refer to FLT5CRES description.
Bits 21:18 FLT3CNT[3:0]: Fault 3 counter
Refer to FLT5CNT description.
Bit 17 FLT3BLKS: Fault 3 blanking source
Refer to FLT5BLKS description.
Bit 16 FLT3BLKE: Fault 3 blanking enable
Refer to FLT5BLKE description.
Bit 15 FLT2RSTM: Fault 2 reset mode
Refer to FLT5RSTM description.
Bit 14 FLT2CRES: Fault 2 counter reset
Refer to FLT5CRES description.
Bits 13:10 FLT2CNT[3:0]: Fault 2 counter
Refer to FLT5CNT description.
Bit 9 FLT2BLKS: Fault 2 blanking source
Refer to FLT5BLKS description.
Bit 8 FLT2BLKE: Fault 2 blanking enable
Refer to FLT5BLKE description.