EasyManuals Logo

Stanley SCD12 Instruction Manual

Stanley SCD12
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
ENGLISH (Original Instructions)
33
TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
Unit will not start.
Battery pack not installed properly. Check battery pack installation.
Battery pack not charged.
Check battery pack charging
requirements.
Unit starts immediately upon inserting
battery.
The switch has been left in the “on”
position.
The switch must be moved to “off
to prevent the tool from immediately
starting when battery is inserted
Battery pack will not charge
Battery pack not inserted into charger.
Insert battery pack into charger until
LED lights.
Charger not plugged tin.
Plug charger into a working out let.
Refer to “Important Charging Notes”
for more details.
Surrounding air temperature too hot
or too cold.
Move charger and battery pack to a
surrounding air temperature of above
40 degrees F (4,5°C) or below 105
degrees F (+40,5°C).
Unit shuts off abruptly.
Battery pack has reached its maximum
thermal limit.
Allow battery pack to cool down.
Out of charge. (to maximize the life
of the battery pack it is designed to
shutoff abruptly when the charge is
depleted.)
Place on charger and allow to charge.

Other manuals for Stanley SCD12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stanley SCD12 and is the answer not in the manual?

Stanley SCD12 Specifications

General IconGeneral
BrandStanley
ModelSCD12
CategoryDrill
LanguageEnglish

Related product manuals