Error
Code
Name Description Diagnosis
Command
Used
42 ERR_MCB_INCL_STUCK
Fit CPU reports MCB error status:- In-
cline stuck
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
Product Model in Maintenance Mode
and ensure it is correct .
3) Re-calibrate the Incline .
4) If the problem persists, check to see
that the Incline Counts value in the
Incline Calibration Screen is changing
during incline calibration .
The Incline Counts should go down as
the elevation goes up .
5) If the Incline Counts is not changing
during calibration, then the cable from
the elevation motor to the MCB should
be checked .
If the cable is OK then the elevation
motor should be replaced.
FIT_ERROR
43 ERR_MCB_UNKNOWN_ERROR
Fit CPU reports MCB error status:- Un-
known error status from MCB
(This error is a place holder for future
error codes from the MCB)
FIT_ERROR
255 ERR_E_STOP
Fit CPU detected emergency stop
condition
1) Reset the E-Stop switch and the prod-
uct will become operational again .
2) If the problem persists, check the
cables/connections in the Hot Bar .
Also check the e-stop cable from the
Hot Bar that plugs into the FitCPU .
3) If the problem still persists check the
comms cable between the FitCPU and
the Translator Board .
4) If all of the above is OK then replace
the Translator Board.
FIT_ERROR