14
Maintenance Mode
Parameters Lowest
Value
Highest
Value
Option 1 Option 2 Default
Value
Meaning
ACCEL TIME
25 60 --- --- 25 Time, in seconds, to
reach max speed.
DECEL TIME
20 60 --- --- 20 Time, in seconds, to
reach 0 mph (0km/hr)
LOCK OUT
--- --- ON OFF OFF OFF = disabled
ON = enabled
LOCKOUT ID
10000 65535 12345 Treadmill Lockout ID
RAIL STOP
--- --- ON OFF OFF OFF = Disables Euro
handrail stop.
ON = Enables Euro
handrail stop
10 REV
22.0 74.0 30.7 = For
110v units
35.6 = For
220v unit
30.7 Inches of belt traveled
for 10 revolutions,
1.6” pulley:27.5
1.7” pulley: 29.1
1.8” pulley:30.7 (110v)
2.1” pulley:35.8(220v)
CNT/RV
1 31 31 =
Magnetic
RPM Sensor
31 =
Magnetic
RPM Sensor
125 Number of counts per
RPM Revolution.
MN PWM
2 100 --- --- 60 Minimum PWM
automatically done.
1/2 PWM
150 300 --- --- 260 1/2 Maximum PWM
automatically done.
MX PWM
380 512 --- --- 440 Maximum PWM
automatically done.
DATE
--- --- --- --- 0 Manufacturing date.
NO RAIL
STOP
0 255 --- --- 0 # of times the Stop
Switch/ Stop key was
down or disconnected
on power-up since last
reset.
KEY DN
0 255 --- --- 0 # of times, one of the
keys was down or
depressed on power-
up since last reset.
SPEED CHG
0 255 --- --- 0 # of times a sudden
change in speed was
detected.
EL STL
0 255 --- --- 0 # of times an elevation
stall was detected.