15
Maintenance Mode
Parameters
Lowest
Value
Highest
Value
Option 1 Option 2 Default
Value
Meaning
EL RANGE
0 255 --- --- 0 # of times elevation
range was detected.
(EL Range will detect
between the Pot read
of 253 and 255).
EL LOST
0 255 --- --- 0 # of times elevation
range was detected.
(EL Lost will detect
when the display has
lost the elevation
motor Pot reading).
NO MOTOR
0 255 --- --- 0 # of times No Motor
was detected.
(display when there’s
no motor current
detected, but there is
belt movement).
NO
SENSOR
0 255 --- --- 0 # of times No Sensor
was detected.
(No Sensor will
display when there’s
no RPM feedback).
ELEV
ZERO
175 242 --- --- 240 Voltage to elevation
motor to obtain 0%.
Multiply by 0.0196608
to = actual voltage.
ELEV MAX
25 170 --- --- 57 = 120V
Black motor
25 = 120v
Silver motor
80 = 230V
Voltage to elevation
motor to obtain 15%.
Multiply by 0.0196608
to = actual voltage
LAST
DECK
0 65565 --- --- 0 # of miles when the
deck was last waxed.
After a 2000 mile (or
3000 KM) difference,
“REWAX BELT” will
scroll in the display
until “LAST DECK”
miles are updated.
LAST BELT
0 65535 --- --- 0 # of miles when the
last running belt was
replaced.
LAST
MOTOR
0 65535 --- --- 0 # of miles when the
last motor was
replaced.
MASTER
PIN
--- --- 13579 13579 13579 Master pin personal
trainer configuration.