– 32 –
No. 1 2 3 4 5 6 7 8 No. 1 2 3 4
DIP-SW 1 DIP-SW 2
11-1. Parallel Interface Model
ON ON
OFF OFF
DIP-SW 1
Switch 1-1 Command emulation
ON Star Mode
OFF ESC/POS Mode
The factory settings of DIP switch are all on.
The functions of switches 1-2 through 1-8 will change according to the command emulation
that has been set using switch 1-1.
(1) Star mode
Switch Function ON OFF
1-1 Command emulation Always ON
1-2 Should not be changed (Should be set to on)
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 Pin #31 (INIT) reset signal Valid Invalid
1-6 Handshaking conditions
(conditions for BUSY)
Offline or receive
buffer full
Receive buffer full
1-7 Automatic status back function Invalid Valid
1-8 Should not be changed (Should be set to on)
(2) ESC/POS mode
Switch Function ON OFF
1-1 Command emulation Always OFF
1-2 Graphic adjustment 203 DPI 180 DPI
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 Pin #31 (INIT) reset signal Valid Invalid
1-6 Handshaking conditions
(conditions for BUSY)
Offline or receive
buffer full
Receive buffer full
1-7 Automatic status back function Invalid Valid
1-8 Should not be changed (Should be set to on)