Static Solutions CT-8900 Combo Tester Instructions 1/15/2015
14
Dip Switch Settings for 1000M unit special unit
The following resistance alarm values may be set inside the combo meter.
The factory settings are represented in bold.
(For new dual range meter, remove jumpers W4 and W5. Add jumper W2)
Foot Low sw1
0 (none) off
.75M ON (default)
Wrist Low sw2
0 (none) off
.75M ON (default)
Foot High sw3 sw4 sw5
20M off off off
50M ON off off
100M off ON off
250M ON ON off
350M off off ON
500M ON off ON
750M off ON ON
1000M ON ON ON (default)
Wrist High sw6 sw7 sw8
20M off off off (default)
50M ON off off
100M off ON off
250M ON ON off
350M off off ON
500M ON off ON
750M off ON ON
1000M ON ON ON
1
2
3
4
5
6
7
8
ON

Table of Contents