Static Solutions CT-8900 Combo Tester Instructions 1/15/2015
73
MAINTENANCE AND CALIBRATION
MAINTENANCE
The meter test button should be occasionally cleaned to remove any buildup of dirt, wax, or finger oils.
The meter foot plate should be occasionally cleaned to remove any buildup of dirt, wax, or other foreign materials.
If the meter is run on battery power, the battery will need to be occasionally replaced after 20,000 or so readings
CALIBRATION TESTING
The combo tester is self-calibrating, but it can be tested by either:
sending it back to your distributor,
testing it with Combo Meter Calibration box available from your distributor,
or by testing with three resistors as shown in the following diagram. For the 100M meter use 1M - 90M 1% resistors. For
the 1000M meter use 10M – 800M resistors. The results are displayed in the regular EsdTest program strap test window.