9. Secure the crane using the mounting hardware
provided (see the detail on page 6-2). Note:
longer or shorter cap screws may be
required – recommended thread
engagement into crane base is 1.75” – use
grade 8, zinc plated cap screws only
.
10. Torque the cap screws to 680 ft-lbs.
11. Remove supporting crane.
12. Hook-up hydraulics and electrical using the schematics provided in
Chapter 8 - Hydraulics -
Electrical
.
Note: If questions should arise during any portion of this installation, please
contact Stellar Customer Service at (800) 321-3741.
Chapter 6 - Installation
6-4