INSSTCP5MA0116
4
Parts Supplied:
one (1) thermostat;
two (2) mounting screws;
four (4) solderless connectors suitable for copper wires;
one (1) oor sensor.
Selection of thermostat and sensor location
The thermostat must be mounted on a connection box, at
around 1.5 m (5 feet) above the oor level, on a section of the
wall exempt from pipes or air ducts.
Do not install the thermostat in a location where
temperature measurements could be altered. For
example:
close to a window, on an external wall, or close to a door
leading outside;
exposed directly to the light or heat of the Sun, a lamp, a
replace or any other heat source;
close or in front of an air outlet;
close to concealed ducts or a chimney; and
in a location with poor air ow (e.g. behind a door), or with
frequent air drafts (e.g. head of stairs).
To install the sensor, refer to the installation guide of your
heating oor.
Thermostat mounting and connection
1. Cut off power supply on lead wires at the electrical
panel in order to avoid any risk of electric shock;
Ensure that the thermostat will be installed on a
junction box located in an uninsulated wall;
2. Ensure that the air vents of the thermostat are clean and
clear of any obstructions;
INSTALLATION