INSSTCP5MA0116
4
Parts Supplied:
• one (1) thermostat;
• two (2) mounting screws;
• four (4) solderless connectors suitable for copper wires;
• one (1) oor sensor.
Selection of thermostat and sensor location
The thermostat must be mounted on a connection box, at
around 1.5 m (5 feet) above the oor level, on a section of the
wall exempt from pipes or air ducts.
Do not install the thermostat in a location where
temperature measurements could be altered. For
example:
• close to a window, on an external wall, or close to a door
leading outside;
• exposed directly to the light or heat of the Sun, a lamp, a
replace or any other heat source;
• close or in front of an air outlet;
• close to concealed ducts or a chimney; and
• in a location with poor air ow (e.g. behind a door), or with
frequent air drafts (e.g. head of stairs).
To install the sensor, refer to the installation guide of your
heating oor.
Thermostat mounting and connection
1. Cut off power supply on lead wires at the electrical
panel in order to avoid any risk of electric shock;
Ensure that the thermostat will be installed on a
junction box located in an uninsulated wall;
2. Ensure that the air vents of the thermostat are clean and
clear of any obstructions;
INSTALLATION