FLIGHT MANUAL TSA-M, VARIANT S6
Doc.-No.:P400-006.000 E Page: 2-17 Revision: 10
Date of Issue: 07. October 2008 Agency approved Date of Rev.: 06.07.2020
2.15 Fuel ___________________________________________
Fuel to be used: MOGAS
(unleaded gasoline according to
EN 228, min. RON 95)
or AVGAS 100LL
Standard tank, with auxiliary tank (integral tanks in left and right
wing)
Tank Capacity (right): 17.2 US gal / 65 l
Tank Capacity (left, optional): 17.2 US gal / 65 l
Non-useable Fuel (right): 0.55 US gal / 2.1 l
Non-useable Fuel (left): 0.3 US gal / 1 l
AVGAS contains lead, which deposits at the valve lip and in the combustion
chamber. According to ROTAX, AVGAS may only be used when vapor bubbles
form or when other fuel is not available (refer to ROTAX SI-914-019, latest
Revision).
Caution: Only use fuels which are appropriate for the local climate
conditions.
Note: The fuel sensor is calibrated to RON 95. All other fuel types
and mixtures of fuel will cause a lower fuel level indication in
the tanks than actual. The real fuel level has to be
determined visually, optional by using a dip stick (see ch.
7.12.4.1), and compared to the indicated fuel level on the
display in the cockpit. The deviation has to be considered for
flight planning.