Doc.-No.:P400-006.000 E Page: 3-15 Revision: 1
Date of Issue: 07. October 2008 Agency approved Date of Rev.: 28.01.2011
3.9 Fire ____________________________________________
3.9.1 Fire in the Engine-Compartment
If the red Fire-Warning light comes on and an alarm signal buzzes or if there is
smell of fire or smoke in flight, the following procedure is recommended:
In flight:
instantly:
1.
Fuel-shut-off-valve
CLOSE (rotate)
2. Throttle FULL POWER (to drain fuel-
lines and float-chambers)
When the engine has stopped:
3.
Ignition
OFF
4. Air-speed 55 kts - 65 kts /
100 km/h - 120 km/h
5.
left Propeller-switch
MANU
6. right Propeller-switch FEATHER
Caution: Final position is
reached not until 90 sec!
7.
Engine-master-switch
OFF
8. Cabin-ventilation
(side-window and/or nozzle)
OPEN in case of smoke in
cockpit
9. Emergency-descent INITIATE as soon as possible.
EXTEND air-brakes to perform.
10. Off-field-landing PREPARE for next suitable
terrain.
Warning: When the master-switch is OFF, the COM and all electrical
equipment is turned OFF (including elevator-trim and
propeller-feathering). It is possible to manually override the
trim.
Caution: The propeller and engine will normally continue to rotate.
The only indication that the engine is not running is the
display on the manifold-pressure-gauge.