Flight Manual STEMME S6
Doc.-No.:P400-006.000 E Page: 3-9 Revision: ---
Date of Issue: 07. October 2008 Agency approved Date of Rev.: --.--.----
3.7 Recovery from Spiral-Dive _________________________
Caution: With middle and forward CG-positions, the spinning A/C has
the tendency to start a spiral-dive after some spinning-turns.
During a spiral-dive, the air-speed and g-forces will increase
in a short time.
Spiral-dive Recovery:
1.
Rudder and Aileron
STOP ROTATION (Deflect in
the direction opposite to the
turn)
2.
Elevator
PULL OUT of the dive with
caution
Warning: Do not exceed V
NE
= 145 kts / 270 km/h during the recovery.
Note: If the A/C stops the spin by itself, it can start a spiral-dive.