Table 2.2 AS380 series elevator integrated drive controller technical specification
2S0
1P5
2S02
P2
2S03
P7
4T0
2P2
4T0
3P7
4T0
5P5
4T0
7P5
4T0
011
4T0
015
4T00
18
4T0
022
4T00
30
4T0
037
4T0
045
4T00
55
4T0
075
Max matching motor
capacity(kW)
1.1 2.2 3.7 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Rated output
Rated capacity
(kVA)
2.3 4.6 6.9 4.7 6.9 8.5 14 18 24 29 34 50 61 74 98 130
Rated current
(A)
6.0 12 18 6.2 9 13 18 27 34 41 48 65 80 97 128 165
Max output
voltage (V)
200V:single-phase 220~240(matching input voltage)
400V:three-phase 380/400/415/440/460V(matching input voltage)
Input power
Phase number
voltage
frequency
200V:single-phase 220~240V、50/60Hz
400V:three-phase 380/400/415/440/460V、50/60Hz
Voltage range
allowed
-15%~+10%
Frequency
range allowed
-5%~+5%
Endurance
capacity of
instantaneous
voltage drop
200V:keep running at AC150V or above; Activate under-voltage protection
after 15ms from the moment when it drops from rated input condition to
somewhere lower than AC150V.
400V:keep running at AC300V or above;Activate under-voltage protection
after 15ms from the moment when it drops from rated input condition to
somewhere lower than AC300V.
basic characteristics
Max accessible
floor
2~64 floors for single elevator
Elevator
running speed
≤4.00m/s
Units under
Group control
≤8 台
Communication
mode
CAN bus serial communication
Operation
function
see section 3.1 for product function list
chara
Control mode PG card vector control
Startup torque 150% 0Hz(PG card vector control)