EasyManuals Logo

STEP AS380-4T0011 User Manual

Default Icon
271 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
243
F35
Firefighting switch input
definition and firefighting
mode selection
0 065535 ×
Bit0: 0: ordinary
firefighting, 1:
Schindler fire mode
Bit1: 0: fireman
switch without lift car
board; 1: fireman
switch with lift car
board
Bit2: 0: ordinary
firefighting signal
display; 1: Shandong
firefighting signal
display
Bit3: 0: Motherboard
X15 input for
firefighting return; 1:
Motherboard X15
input for fireman
switch
F36 Band-type Brake switch
detection mode
0 02 ×
F40 Weight data bias 48 0100 %
F41 Weighter study and
parameter setup
command.
0 012
102030
4050
60
×
F43 Buzzing/flashing function
selection for attendant
status call
3 065535 × .
F44 Serial communication
address (255 for
non-monitor)
255 0255 ×
F49 Emergency leveling
orientation mode
0 02
F50 Front door opening
permission 1 (opening
setup value for 1 16
floors)
65535 065535 ×
F51 Front door opening
permission 2 (opening
setup value for 17 32
floors)
65535 065535 ×