Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
56
JP8
JP8.1 X0
Inspection signal 1 , disconnection as
inspection,X0 and X1 all connected as
automatic
Input
Normal
close
JP8.2 X1
inspection signal 2, disconnection as
inspection, X0 and X1 all connected as
automatic
Input
Normal
close
JP8.3 X2
move up signal ,inspection, inch moving
up, attendant, move up and change
direction
Input
JP8.4 X3
move down, inspection, inching move
down, attendant, move down and change
direction
Input
JP8.5 X4
upward No 1 terminal deceleration
switch
Input
Normal
close
JP8.6 X5
Downward No 1 terminal deceleration
switch
Input
Normal
close
JP8.7 X6 upper leveling switch Input
JP8.8 X7 under leveling switch Input
JP8.9 X8 motor power supply contactor inspection Input
Normal
close
JP8.10 X9 band brake contactor inspection Input
Normal
close
JP9
JP9.1 X10 left band brake switch Inspection Input
JP9.2 X11 right band brake switch inspection Input
JP9.3 X12 motor temperature inspection signal Input
JP9.4 X13 door pre-opening relay inspection Input
JP9.5 X14 door zone signal inspection Input
JP9.6 X15
firefight return/ firemen switch
( parameter selection)
Input
JP9.7 X16
blackout emergency leveling
input/earthquake/ building backup power
supply( parameter selection)
Input