COMMISSIONING
Menu
16 | WPM www.stiebel-eltron.com
Menu: PROGRAMS
 SETTINGS
!
Material losses
Incorrect settings can cause damage to the heat pump
or screed. The temperatures and time periods must be
specified by the screed contractor responsible.
Ask the screed contractor responsible for the details
required.
1
7
4 5
3
2
84_03_01_0038
6
Y Temperature
X Time
1 Maximum temperature (MAXIMUM TEMPERATURE)
2 Low end temperature (LOW END TEMPERATURE)
3 Duration of low end temperature (DURATION BASE TEMP)
4 Rise K/day (RISE PER DAY)
5 Duration of maximum temperature (MAX TEMPERATURE
DURATION)
6 Start
7 End
Note
On expiry of the period over which the screed is heated
to maximum temperature, the temperature is reduced in
equal steps to the low end temperature.
Six parameters are available to determine the temperatures and
periods for the heat-up program. These parameters can be ad-
justed sequentially as soon as the heat-up program is activated.
Set the program to ON using the Touch-Wheel. Confirm the
selection with OK.
Use the Touch-Wheel to select the parameter you want to set.
Confirm the selection with OK.
Use the Touch-Wheel to set the desired value. Confirm the
selection with OK.
Adjust the other parameters in the same way.
 LOW END TEMPERATURE
Here you can set the temperature to which the screed is initially
heated.
 DURATION BASE TEMP
Here you can set how long the LOW END TEMPERATURE is main-
tained.
 MAXIMUM TEMPERATURE
Here you can set the maximum temperature to which the screed
is heated.
 MAX TEMPERATURE DURATION
Here you can set how long the MAXIMUM TEMPERATURE is main-
tained.
 RISE PER DAY
Here you can set by how many degrees Kelvin the temperature
rises before the MAXIMUM TEMPERATURE is reached.
PASTEURISATION PROGRAM
Note
For the PASTEURISATION PROGRAM, an emergency/
booster heater or external heat source must be connect-
ed.
In menu item PASTEURISATION PROGRAM, you can specify the
days and times at which the DHW cylinder heats the content to
the highest value.
 START TIME
Here you can specify the start time at which the DHW cylinder
heats the content to the highest value.
 DAYS
Here you can set the days on which the DHW cylinder heats the
content to the highest value.
DHW CIRCULATION PROGRAM
Select DHW CIRCULATION PROGRAM to determine the times during
which the DHW circulation pump is controlled according to the
time program.
SWIMMING POOL PROGRAM
Select SWIMMING POOL PROGRAM to determine the times during
which swimming pool water heating should take place. Outside
those times, the swimming pool water heating will be switched
off.
Note
You can adjust the set value under SETTINGS/ SWIMMING
POOL/ SET TEMPERATURE.
SILENT PROGRAM 1
Select SILENT PROGRAM 1 to determine the times during which
the heat pump is offset to a reduced noise mode.
By reducing the fan speed, the noise level of the heat pump is
reduced. On certain heat pumps, the compressor power may also
be reduced.