COMMISSIONING
Settings
www.stiebel-eltron.com WPM | 41
9. Settings
9.1 Parameter overview
The following lists the parameters that can be adjusted via the programming unit.
Note
The values in the columns "Min.", "Max." and "Standard" vary depending on the connected heat pump and may differ from the
values given.
Menu item/parameter Options Unit Min. Max. Standard System value
PROGRAMS
PARTY PROGRAM
HOURS h 0 24
HEAT-UP PROGRAM
SETTINGS
LOW END TEMPERATURE °C 20 40 25.0
DURATION BASE TEMP d 0 5 2
MAXIMUM TEMPERATURE °C 20 50 40.0
MAX TEMPERATURE DURATION d 0 5 0
RISE PER DAY K 1 10 1
SETTINGS
GENERAL
CONTRAST 1 5
BRIGHTNESS % 0 100 50
TOUCH SENSITIVITY 1 10 4
TOUCH ACCELERATION 1 10 6
HEATING
HEATING CIRCUIT 1
COMFORT TEMPERATURE °C 5 30 20
ECO TEMPERATURE °C 5 30 20
MINIMUM TEMPERATURE OFF °C 10 30 OFF
ROOM INFLUENCE % 0 100
HEATING CURVE RISE 0.2 3 0.6
HEATING CIRCUIT 2/ 3/ 4/ 5
COMFORT TEMPERATURE °C 5 30 20
ECO TEMPERATURE °C 5 30 20
MINIMUM TEMPERATURE OFF °C 10 30 OFF
MAXIMUM TEMPERATURE °C 20 90 50
MIXER DYNAMICS 30 240 100
ROOM INFLUENCE % 0 100
HEATING CURVE RISE 0.2 3 0.2
STANDARD SETTING
BUFFER OPERATION OFF | ON
SUMMER MODE OFF | ON ON
OUTSIDE TEMPERATURE °C 10 30 20
BUILDING HEAT BUFFER 0 3 1
FLOW PROP HEATING CIRC % 0 100
MAXIMUM RETURN TEMP °C 20 65 65
MAXIMUM FLOW TEMPERATURE °C 20 75 75 °C
FIXED VALUE OPERATION OFF °C 20 70 OFF
HEATING CIRCUIT OPTIMAL OFF 0.01 0.1
FROST PROTECTION °C -10 10 4 °C
REMOTE CONTROL FE7
ROOM INFLUENCE OFF 0 20 5
ROOM CORRECTION K -5 5 0
PUMP CYCLES OFF | ON
EXTERNAL HEAT SOURCE
OFF OFF | ON
THREADED IMMERSION HEATER OFF | ON
BOILER OFF | ON