0458-620-0121-A
34
English
19 Specifications
– Degree of electrical protection: IPX5 (protection from
water jets in any direction)
– Working pressure (p): 12.5 MPa (125 bar)
– Max. permissible pressure (p max.): 14 MPa (140 bar)
– Max. water supply pressure (p in max.): 1 MPa (10 bar)
– Max. water throughput (Q min): 8.3 l/min (500 l/h)
– Max. suction lift: 1 m
– Max. water temperature in pressure mode (t in max):
40 °C
– Max. water temperature in suction mode: 20 °C
– Dimensions
– Length: 419 mm
– Width: 371 mm
– Height in operating position: 925 mm
– Height in transport position: 650 mm
– Length of high-pressure hose: 8 m
– Weight (m) with accessory attached: 20 kg
Version 240 V / 50 Hz
– Fuse (characteristic "C" or "K"): 10 A
– Power consumption: 2.1 kW
– Electrical protection class: I
– Degree of electrical protection: IPX5 (protection from
water jets in any direction)
– Working pressure (p): 12.5 MPa (125 bar)
– Max. permissible pressure (p max.): 14 MPa (140 bar)
– Max. water supply pressure (p in max.): 1 MPa (10 bar)
– Max. water throughput (Q min): 8.3 l/min (500 l/h)
– Max. suction lift: 1 m
– Max. water temperature in pressure mode (t in max):
40 °C
– Max. water temperature in suction mode: 20 °C
– Dimensions
– Length: 419 mm
– Width: 371 mm
– Height in operating position: 925 mm
– Height in transport position: 650 mm
– Length of high-pressure hose: 8 m
– Weight (m) with accessory attached: 19.9 kg
Version 220 V / 50 Hz
– Fuse (characteristic "C" or "K"): 10 A
– Power consumption: 2.1 kW
– Electrical protection class: I
– Degree of electrical protection: IPX5 (protection from
water jets in any direction)
– Working pressure (p): 12.5 MPa (125 bar)
– Max. permissible pressure (p max.): 14 MPa (140 bar)
– Max. water supply pressure (p in max.): 1 MPa (10 bar)
– Max. water throughput (Q min): 8.3 l/min (500 l/h)
– Max. suction lift: 1 m
– Max. water temperature in pressure mode (t in max):
40 °C
– Max. water temperature in suction mode: 20 °C
– Dimensions
– Length: 419 mm
– Width: 371 mm
– Height in operating position: 925 mm
– Height in transport position: 650 mm
– Length of high-pressure hose: 8 m
– Weight (m) with accessory attached: 20 kg
19.3 Extension Cords
If an extension cord is used, the cross sectional area of its
conductors must meet the following minimum requirements
– depending on the line voltage and length of the extension
cord: