StoneL publication 105431revC
7 PI 70 en Prism PI | 17
4.2.1 VCT with DeviceNet™ communication (92S & 92W) continued
Caution:
Power cycling unit with Byte 0, Bit 3 or Bit 4 set
will cause the sensor(s) to set at that valve position. Ensure
Byte 0, Bit 3 and Bit 4 are reset to 0 after performing a
remote sensor setting.
Remote sensor setting feature
The Remote Sensor Setting feature provides the capability of setting
the closed and open sensors remotely from the control system.
1. DeviceNet™ communications are required in order to remotely set
the sensors. The unit must be addressed and correctly congured
to be recognized by the control system.
2. With the valve/actuator in the closed position, set byte 0, bit 3 to
“1” for at least two seconds. This will set the closed sensor to that
valve/actuator position. Set byte 0, bit 3 back to “0”
3. With the valve/actuator in the open position, set Byte 0, Bit 4 to “1”
for at least two seconds. This will set the open sensor to that valve/
actuator position. Set byte 0, bit 4 back to “0”
Wink feature
The Wink feature provides the capability of setting the closed or open
LEDs to simultaneously ash or wink at a 2Hz rate. This feature aids in
physically locating the unit on the network.
1. DeviceNet™ communications are required in order to set the Wink
feature. The unit must be addressed and correctly congured to be
recognized by the control system.
2. Set byte 0, bit 2 to “1” in the desired unit. Once the correct unit has
been physically located on the network, indicated by the winking
of the LEDs, set byte 0 bit 2 back to “0”. Performing this function
will not change the closed and open sensor setpoints.
Fault Bit (input byte 0, bit 7)
The Fault Bit will set to a 1 when input byte 0, bits 0 and 1 are set to 1
or 0 at the same time.
When input byte 0, bits 0 and 1 are both set to 1, this would indicate
that the valve is both open and closed at the same time. This would
be an abnormal or Fault condition.
Specications for Wireless Link
Communication Bluetooth® technology; single mode
(not compatible with Bluetooth® Classic)
Frequency band 2.402-2.480 Ghz
Transmit power 4dBm or ~2.5 milliwatts
Data rate 1 Mbit/second; eective information transmit rate
~10 Kbits/second
Range Up to 100 meters (330 feet) in free space. Range is
reduced by obstructions between handheld device and
Wireless Link VCT. Line of site is not necessary.
Registrations FCC, IC, CE
CE compliance Exceeds industrial compliance standards
VCT identication VCTs in range will be displayed in order of signal
strength
VCT link One device accessed at a time between client (hand-
held device) and server (VCT). Each server accessed by
one client at a time
Application StoneL Wireless Link available from the App store
Hand-helds Compatible with iPhone® and iPad® with iOS 8 or later