Caution
To avoid exposure to skin irritants,
wear protective gloves (provided)
throughout this procedure.
DOC-34032 Rev. A
Question and Answer IconNeed help?

Do you have a question about the Stratasys Objet Series and is the answer not in the manual?

Summary

Support Print Head Removal

Preparation for Support Print Head Removal

Put on protective gloves, remove specific screws, and loosen an adjustment screw.

Print Block Cover and Head Card Removal

Remove the print block cover, then detach the support print head card and loosen thumb screws.

Support Print Head Detachment and O-Ring Seal Removal

Hold the print head, press thumb screws, and remove it along with O-ring seals.

Print Head UV Protection and Disposal

Protect print head from UV light if re-installing or discard according to regulations.

Support Print Head Installation

O-Ring Seal and Positioning Jig Alignment

Ensure O-ring seals are on the print head and align it correctly in the positioning jig.

Jig Operation and Thumb Screw Tightening

Push jig upwards at marked points and tighten print head thumb screws.

Head Card Attachment and Jig Removal

Attach the print head card to the print block and remove the positioning jig.

Print Block Cover and Screw Installation

Install the print block cover and insert/tighten specified screws.

Model Print Head Removal

Model Print Head Card and Thumb Screw Loosening

Remove the model print head card and loosen the print head thumb screws.

Model Print Head Detachment and O-Ring Seals

Hold the print head, press thumb screws, remove it, and ensure O-ring seals are taken.

Model Print Head UV Protection or Disposal

Protect the model print head from UV light if re-installing, or discard it properly.

Model Print Head Installation

O-Ring Seals and Positioning Jig Alignment

Confirm O-ring seals are installed on the print head and align it in the positioning jig.

Jig Operation and Thumb Screw Tightening

Push the jig upwards at marked locations and tighten the model print head thumb screws.

Head Card Attachment and Jig Removal

Press the model print head card firmly to attach it and remove the jig.

Stratasys Objet Series Specifications

General IconGeneral
TechnologyPolyJet
SoftwareObjet Studio
Layer Thickness16 microns
Layer Resolution600 x 600 dpi
Applicationsmedical models
Material OptionsRigid, flexible, transparent, and biocompatible materials
Print SpeedVaries depending on model and print mode
ConnectivityEthernet
Power RequirementsVaries depending on the specific Objet model
DimensionsVaries depending on the specific Objet model
WeightVaries depending on the specific Objet model

Related product manuals