Stratasys uPrint SE Plus
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Operating temperature shall be in the range of 59°F to 86°F (15°C to 30°C), with relative
humidity range of 30% to 70% non-condensing.
Storage temperature shall be in the range of -40°F to 129.2°F (-40°C to 54°C), with relative
humidity range of 10% to 85% non-condensing.
Altitude shall not exceed 6561.68 feet (2000 m).
Typical heat emission shall be 2250 BTU/hour.
Idle sound pressure at bystander <55 dBA (idle), operating sound pressure at bystander <62
dBA (printing).
POWER CONSUMPTION
WORKSTATION REQUIREMENTS
For details, see the CatalystEX Workstation Requirements document available from the Stratasys website.
ELECTRICAL REQUIREMENTS
AC POWER REQUIREMENTS
100 - 240VAC
50/60Hz
12 - 7A
1200W dedicated circuit
The grounded electrical outlet must connect to either a Euro or a US power cord plug provided
and must be located within 2 m (80 inches) of the printer.
Operation of the printer outside this range is not recommended; degradation of performance and shortened
component life expectancy will be experienced.
LAN REQUIREMENTS
A LAN connection is required for communication and file transfer functions.
The LAN connection is a 100 base T, Ethernet protocol, RJ45 connector. One CAT5, 10/100 base T cable is
supplied with the printer, located in the Startup Kit.
The LAN connection must be located within 4 m (14 feet) of the printer.
The printer will function in either DHCP or Static IP configurations.
Power Consumption
(while building)
~750W
Caution: Do not use an extension cord or power strip; doing so can result in
intermittent power issues. Connect the power cord directly into the receptacle or
UPS.
Note: Printers configured with a network option of UPnP=ON will occasionally
broadcast a unique system identifier across the network for use by the Catalyst
software application.
Refer to Catalyst’s user information for workstation requirements.