4.3.1.10 A1: Limiter Threshold
Disconnect all dummy load resistors.
Steps Generator Measurement
No. Description Id Value Test pos. Type Value Limits
1 HF limiter G1 +10 dBV/10 kHz/sine wave M1 * Level +8.5 dBV ±2 dBV
2 LF limiter G1 +10 dBV/100 Hz/sine wave M1 * Level +7.3 dBV ±2 dBV
* The Mw and Mt output levels must be reduced.
Limiter Threshold
0
+40
+10
+20
+30
[dBV]
20
20 k
50 100 200 500 1 k 2 k 5 k 10 k