Studer A1 - A1: Measurement Setup in the Anechoic Room

Studer A1
93 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A Series Active Monitor Speakers
E4/10 Service Date printed: 29.02.00
4.3.2.4 A1: Measurement Setup in the Anechoic Room
Setup the loudspeaker;
Setup the measurement microphone:
- Distance to the baffle 1 m,
- Equidistant from the two vertical edges,
- Equidistant from the centers of woofer and tweeter units (i.e., h =
16 cm), and
- Perpendicular to the baffle;
Connect your unit to the mains, set power switch to ON, check the current
consumption ( < 50 mA
AC
for 230 V);
Connect generator G1 with correct signal polarity.
Note: For more information on frequency response measurements, please refer
to section 4.6 .
h
1 m
=
=
G1
M2
L
N
M1
A1
C
P1
M3