EasyManua.ls Logo

Studer RCC-03 - Page 86

Studer RCC-03
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Studer Innotec SA
RCC-02/-03
82 V4.4.0 User manual
Level
User
ref.
Parameter
Unit
12
24
48
Modi.
val
Factory
Min
Max
Factory
Min
Max
Factory
Min
Max
Expert
5045
Load Xtender parameters preset
Choose
1
-
-
1
-
-
1
-
-
Expert
5051
Save and restore BSP files
Expert
5052
Save BSP parameters
-
-
-
-
-
-
-
-
-
Expert
5053
Load BSP parameters
-
-
-
-
-
-
-
-
-
Inst.
5054
Create BSP configuration file (masterfile)
-
-
-
-
-
-
-
-
-
Expert
5055
Load BSP configuration file (masterfile)
-
-
-
-
-
-
-
-
-
Expert
5084
Save and restore VarioTrack files
Expert
5085
Save VarioTrack parameters
-
-
-
-
-
-
-
-
-
Expert
5086
Load VarioTrack parameters
-
-
-
-
-
-
-
-
-
Inst.
5087
Create VarioTrack configuration file (masterfile)
-
-
-
-
-
-
-
-
-
Expert
5088
Load VarioTrack configuration file (masterfile)
-
-
-
-
-
-
-
-
-
Expert
5063
Save and restore MPPT Tristar files
Expert
5064
Save MPPT Tristar parameters
-
-
-
-
-
-
-
-
-
Expert
5065
Load MPPT Tristar parameters
-
-
-
-
-
-
-
-
-
Inst.
5066
Create MPPT Tristar configuration file (masterfile)
-
-
-
-
-
-
-
-
-
Expert
5067
Load MPPT Tristar configuration file (masterfile)
-
-
-
-
-
-
-
-
-
Inst.
5047
Format the SD card
-
-
-
-
-
-
-
-
-
Expert
5061
Start update
-
-
-
-
-
-
-
-
-
Inst.
5042
MODIFICATION OF ACCESS LEVELS OF MANY
PARAMETERS
Inst.
5043
Change all parameters access level to:
Text
Choose
-
-
Choose
-
-
Choose
-
-
Inst.
5044
Restore default access level of all parameters
-
-
-
-
-
-
-
-
-
Basic
5007
BACKLIGHT
Basic
5093
Backlight mode
Text
Delayed
-
-
Delayed
-
-
Delayed
-
-
Basic
5009
Backlight switch off after
sec
120
5
120
120
5
120
120
5
120
Expert
5026
Red backlight flashing on Xtender off and faulty
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Basic
5021
EXTENDED AND SPECIAL FUNCTIONS
Basic
5006
Display contrast
%
45
0
100
45
0
100
45
0
100
Expert
5073
Choice of standard display
Text
Xtender
-
-
Xtender
-
-
Xtender
-
-
Expert
5010
Come back to standard display after
sec
600
5
600
600
5
600
600
5
600
Expert
5011
Visibility of the transitory messages
sec
60
0
180
60
0
180
60
0
180
Basic
5027
Acoustic alarm active
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
5031
Remote control acoustic alarm duration
sec
120
5
120
120
5
120
120
5
120
Expert
5056
Switching ON and OFF of system on level "VIEW ONLY"
No/Yes
Yes
-
-
Yes
-
-
Yes
-
-
Expert
5071
Reset of all the remotes control
-
-
-
-
-
-
-
-
-
Expert
5121
Reset all devices of the system
-
-
-
-
-
-
-
-
-

Table of Contents

Other manuals for Studer RCC-03