Electronic Control System
3-19
#3758407 - Revision B - August, 2006
POSSIBLE ERROR INDICATORS
These pages contain diagrams illustrating what a customer may see on the LCD if there is a problem with the unit.
NOTE: To clear indicators and error codes, problem must be corrected then press Bell ON/OFF key for 15 seconds.
NOTE: For thermistor errors described below, thermistor can be tested by submersing it in a glass of ice water for 2
to 5 minutes, then check for 30,000 to 33,000 ohms.
Figure 3-34. “ICE” & “SERVICE” Flashing = Valve Solenoid energized 15 Sec., Icemaker System Disabled
Figure 3-33. “40”, or “50” and “SERVICE” and “EC” Flashing = Excessive Compressor Run
Figure 3-35. “SERVICE” Steady, not Flashing = Error Codes Observed in Diagnostic Mode, but not Cleared