EasyManuals Logo

Suburban SW6PR Service Training Manual

Default Icon
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
120 V.A.C. ONLY
CODE
BLACK
BK
COLOR
W
WHITE
HI-
LIMIT T'STAT
BK
BK
BK
SWITCH
BK
W
DISCONNECT POWER SUPPLY BEFORE REMOVING COVER
SUBURBAN MANUFACTURING COMPANY, DAYTON, TENNESSEE
120 V.A.C SINGLE PHASE - 1440 WATT ELEMENT - 60 CYC LE
TOTAL CONNECTED WATTS = 1440 - AMPS = 12
GROUNDING SCREW
ELECTRIC
ELEMENT
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE HE ATER MUST
BE REPLACED, IT MUST BE REPLACED WITH 14 GA. 105°C WIRE OR IT'S
EQUIVALENT.
SI UN DES FILS ELECTIQ
UES LIVRES AVEC LE CHAUFFE-EA U DOIT
ETRE REMPLACE, UTILISER A CET EFFET UN FIL 14 GA. 1 05° OU
EQUIVALENT. 340468
12 V.D.C. ONLY
JUNCTION
BOX
Y
G
BL
R
RED
BLUE
GREEN
YELLOW
BROWN
BR
BK
BLACK
G
BL
R
R
Y
BK
1
2
3
4
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER
HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH 18 GA.,
105°C WIRE OR IT'S EQUIVALENT.
SWITCH
HI-LIMIT T'STAT
MODULE BD.
SPARK CABLE
ELECTRODE
BR
GAS VALVE
LIGHT
( FACTORY WIRING)
( ---- FIELD WIRING)
DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT
AND HI-LIMIT UNDER ACCESS COVER.
1 3 4 6
CAUTION: DO NOT HI-POT (DIELECTIC HIGH VOLTAGE TEST) THIS
UNIT AFTER INSTALLATION. TO DO SO MAY CAUSE COMPONENT
DAMAGE AND VOIDS WARRANTY OF WATER HEATER.
340461
Figure 6
120 V.A.C.
Figure 7
12 V.D.C.
ALL WIRES ARE 18 GA. 105°C UNLESS OTHERWISE SPECIFIED.
TOUS LES CABLES DE CONNEXION SONT DE JAUGE 18/105°C A MOINS
DUNE STIPULATION CONTRAIRE
THIS UNIT IS POLARITY SENSITIVE AND MUST BE WIRED CORRECTLY.
RESPECTER LA POLARITE ET RACCORDER LAPPAREIL CORRECTEMENT.
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
WATER HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH
18 GA., 105°C WIRE OR ITS EQUIVALENT
REMARQUE: SI LUN DES CABLES DORIGINE FOURNIS AVEC LE
CHAUFFEEAU DOIT ETRE REMPLACE, UTILISER UN CABLE DE JAUGE
18/105°C OU DUN CABLE EQUIVALENT
1
2
3
4
5
6
7
4
3 2 1
BK
BK
BK
BK
WH
WH
BR
BR
BR
PR
Y
Y
JUNCTION
BOX
LA BOÎTE
DE DERIVATION
CODE
PR
WH
BK
BR
Y
COLOR
PURPLE
WHITE
BLACK
BROWN
YELLOW
(COULEUR)
(POURPRE)
(BLANC)
(NOIR)
(MARRON)
(JAUNE)
SWITCH
L'INTERRUPTEUR
HI-LIMIT
HAUTE-LIMITE
TSTAT
LE THERMOSTAT
MODULE
BOARD
LA CARTE
MODULE
SPARK CABLE
LE CÂBLE
D'ÉTINCELLE
ELECTRODE
L'ÉLECTRODE
LE TUBE A GAZ
340544
ALL WIRES ARE 18 GA. 105°C UNLESS OTHERWISE SPECIFIED.
14 GA. 105°C WIRE
TOUS LES CÂBLES DE CONNEXION SONT DE JAUGE 18/105°C À MOINS
DUNE STIPULATION CONTRAIRE
14/105°C CÂBLES
THIS UNIT IS POLARITY SENSITIVE AND MUST BE WIRED CORRECTLY.
RESPECTER LA POLARITÉ ET RACCORDER LAPPÀREIL CORRECTEMENT.
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
WATER HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH
18 OR 14 GA., 105°C WIRE AS INDICATED OR ITS EQUIVALENT
REMARQUE: SI LÙN DES CÂBLES D’ORIGINE FOURNIS AVEC LE
CHAUFFEEAU DOIT ÊTRE REMPLACÉ, UTILISER UN CÂBLE DE JAUGE 18
OU 14/105°C TEL QÙINDIQUE OU DUN CÊBLE EQUIVALENT
1
2
3
4
5
6
7
4
3 2 1
JUNCTION
BOX
LA BOÎTE
DE DERIVATION
BK
BK
BK
BK
BK
WH
WH
WH
BR
BR
BR
BK
PR
Y
Y
CODE
PR
WH
BK
BR
Y
COLOR
PURPLE
WHITE
BLACK
BROWN
YELLOW
(COULEUR)
(POURPRE)
(BLANC)
(NOIR)
(MARRON)
(JAUNE)
SWITCH
L'INTERRUPTEUR
HI-LIMIT
HAUTE-LIMITE
TSTAT
LE THERMOSTAT
MODULE
BOARD
LA CARTE
MODULE
SPARK CABLE
LE CÂBLE
D'ÉTINCELLE
ELECTRODE
L'ÉLECTRODE
HI-LIMIT
HAUTE-LIMITE
TSTAT
LE THERMOSTAT
ELECTRIC ELEMENT
ÉLEMENT ELECTRIQUE
SWITCH
L'INTERRUPTEUR
LE TUBE A GAZ
340543
Figure 8
120 V.A.C. SW16V
Figure 9
120 V.A.C. SW16VE
12 V.D.C. ONLY
JUNCTION
BOX
Y
G
BL
R
RED
BLUE
GREEN
YELLOW
BROWNBR
BK
BLACK
G
BL
R
R
Y
BK
1
2
3
4
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER
HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH 18 GA.,
105°C WIRE OR IT'S EQUIVALENT.
SWITCH
HI-LIMIT T'STAT
MODULE BD.
SPARK CABLE
ELECTRODE
BR
GAS VALVE
SWITCH
( FACTORY WIRING)
( ---- FIELD WIRING)
DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT
AND HI-LIMIT UNDER ACCESS COVER.
1 3 4 6
CAUTION: DO NOT HI-POT (DIELECTIC HIGH VOLTAGE TEST) THIS
UNIT AFTER INSTALLATION. TO DO SO MAY CAUSE COMPONENT
DAMAGE AND VOIDS WARRANTY OF WATER HEATER.
*12VDC SIDE OF RELAY 340539
LIGHT
RELAY
O
ORANGE
O
(GAS)
(ELECTRIC)
120 V.A.C. ONLY
DISCONNECT POWER SUPPLY BEFORE REMOVING COVER
CODE
BLACK
BK
COLOR
W WHITE
HI-
LIMIT
T'STAT
BK
BK
BK
SWITCH
BK
W
SUBURBAN MANUFACTURING COMPANY, DAYTON, TENNESSEE
120 V.A.C SINGLE PHASE - 1440 WATT ELEMENT - 60 CYCLE
TOTAL CONNECTED WATTS = 1440 - AMPS = 12
GROUNDING SCREW
ELECTRIC
ELEMENT
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE HEATER MUST
BE REPLACED, IT MUST BE REPLACED WITH 14 GA. 105°C WIRE OR IT'S
EQUIVALENT.
SI UN DES FILS ELECTIQ
UES LIVRES AVEC LE CHAUFFE-EAU DOIT
ETRE REMPLACE, UTILISER A CET EFFET UN FIL 14 GA. 105° OU
EQUIVALENT. *120VAC SIDE OF RELAY
RELAY
BK
*
Figure 10
12 V.A.C. for MODELS SW6, 10, 12, & 16DEL
Figure 11
120 V.A.C. for MODELS SW6, 10, 12, & 16DEL
11

Other manuals for Suburban SW6PR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suburban SW6PR and is the answer not in the manual?

Suburban SW6PR Specifications

General IconGeneral
BrandSuburban
ModelSW6PR
CategoryWater Heater
LanguageEnglish

Related product manuals