4: Operation 600H, 750, 750H, 750HH, 825, 900, 900H, 1050 T3 CAT User Manual
02250197-981 R01
54 Subject to EAR, ECCN EAR99 and related export control restrictions.
4.4 Shutdown procedure
1. Close the service valve.
2. Turn Place the OFF/ON/START switch in the
“OFF” position. The following message will
be displayed in the LCD graphic display:
The unit will continue to run, though it will not
produce usable air. At the end of the cool
down, the engine will be shut down. The con-
troller will stay powered up, and a new mes-
sage will be displayed:
The controller will continue to monitor the
system pressures and will not power down
until all pressures drop below 10 PSI (0.7
bar). This final process may take 3 to 5 min-
utes. Operator interaction is not necessary
during this time as the controller will auto-
matically disconnect power to all systems so
that the battery is not inadvertently drained
after shutdown.
WARNING
The E-Stop (emergency stop switch) should be
used only in the event of an emergency. Refrain
from using the E-Stop to shut the machine down
during normal operations. All usage of the E-
Stop is logged in permanent memory for use by
service technicians when troubleshooting a
machine. Non-emergency use of E-Stop is con-
sidered equipment abuse and could void the
manufacturer’s warranty.