600H, 700, 750, 750H, 750HH, 825, 900, 900H, 1050 T3 CAT User Manual 5: Maintenance
02250197-981 R01
Subject to EAR, ECCN EAR99 and related export control restrictions. 57
5.10 Maintenance every 1500 hours
When using Sullair AWF
®
, change the compressor fluid
and replace the fluid filter element.
Refer to Section 5.11: Parts replacement and adjustment
procedures.
5.11 Parts replacement and
adjustment procedures
5.11.1 Compressor fluid change procedure
Warm-up the compressor for 5 to 10 minutes to warm the
fluid. Shut the compressor off and relieve all internal
pressure before proceeding. Drain the fluid by opening
the appropriate drain valve located in the frame at the
front of the machine. Close the valve when draining is
complete. Change the compressor fluid and replace the
fluid filter element. For element replacement see proce-
dure for servicing the fluid filter
in this section. Fill
the
receiver tank with fluid according to Section 3.4: Lubrica-
tion guide, compressor on pa
ge 42.
5.11.2 Running gear lubrication
Refer to Figure 5-1. An inspection of the running gear
should be made on a routine basis. On four-wheel steer-
able running gear models, front-axle pivot joints and rod
ends ar
e fitted with grease zerks which should be lubri-
cated every six months.