Section 3
SPECIFICATIONS
15
3.1 TABLE OF SPECIFICATIONS- LS20-100HP/ 75KW
60 Hz:
Model (I) HP CAPACITY LENGTH WIDTH HEIGHT (II) WEIGHT (III)
CFM IN IN IN LB
OPEN/ENCL AC/WC
100-L 100 490 88 48 60/61.5 3590/3660
100-H 100 450 88 48 60/61.5 3590/3660
100-HH 100 380 88 48 60/61.5 3590/3660
100-XH 100 344 88 48 60/61.5 3590/3660
50 Hz:
Model (I) KW CAPACITY LENGTH WIDTH HEIGHT (II) WEIGHT (III)
M
3
/MIN MM MM MM KG
OPEN/ENCL AC/WC
100-L 75 14.1 2235 1219 1524/1562 1628/1660
100-H 75 13.0 2235 1219 1524/1562 1628/1660
100-HH 75 11.0 2235 1219 1524/1562 1628/1660
100-XH 75 9.4 2235 1219 1524/1562 1628/1660
(I) Includes standard and 24KT. Rated pressure designations appearing after model number are as fol-
lows:
"L" - 100 psig / 6.9 bar; "H" - 125 psig / 7.9 bar; "HH" - 150 psig / 9.7 bar; "XH" - 175 psig / 12 bar
(II) Add an additional height for servicing the separator as follows:
a) Open: 9 in. / 229 mm
b) Enclosed: 31.5 in. / 610 mm
(III) Add 500 lbs. / 228 kg for enclosure.
For latest sound test data, consult Sullair factory.
COMPRESSOR:
Type: Positive displacement, fluid-lubricated, twin rotary screws
Configuration: Single-stage geared integral drive
Bearing Type: Anti-friction
Lubricant: Pressurized Sullube
Coolant: See sections 3.2 and 3.3 on Lubricant
Sump Capacity: 10 gallons (38 liters)
Control Type: Electro-pneumatic
Options: Spiral valve (direct-drive)
MOT
OR:
Size: 100 HP / 75 KW
Type: C-flanged, Open-dripproof enclosure, Premium Efficiency,
3-phase, 230/460V 60 Hz, 380-415V 50Hz,
104 deg. F / 40 deg. C Maximum Ambient Temperature
Options: Various voltages, TEFC enclosure: CE approved.
Speed: 4-pole (60 Hz - 1770 RPM, 50 Hz - 1475 RPM)
Starter: Full-voltage, Wye-delta, or Solid State; various voltages.