Section 7
TROUBLESHOOTING-SUPERVISOR
35
Table 7-2 Parameters
Type Enable Default Min Max Display Text Comment
Setup Always 1 0 2 Press Trans 250
Setup X250 135 70 225 P1 Max 250psi transducer
Setup Always 0 0 1 Water Switch Water pressure switch enable for water
cooled machines
Setup Flooded 0 0 1 Oil Switch Oil switch enable for flooded screw
machines
Setup Always 65 20 200 Min Load Psi Minimum acceptable Loaded P1 value
Setup Always 0 0 30 Stop Timer If not 0, run unloaded for this time before
stopping
Setup Always 0 0 30 Lube Cycle Prelube/Postlube timer
Setup Always 0 0 2 K8 Option Disable, Lube Pump, Master Control
Setup Always 0 0 100000 Load Hours Hours machine has been loaded
Setup Always 0 0 100000 Run Hours Hours machine has been running
Setup Always 0 0 100000 Load Cycles Number of load cycles
Setup Always 0 0 100000 Starts Number of starts
Setup Always 0 0 10000 Capacity Used by monitor to determine system load
Cal Always 0 -7 7 P1
Cal Always 0 -7 7 P2
Cal Always 0 -20 10 dP1
Cal Always 0 -7 7 P3
Cal Always 0 -7 7 P4
Cal Always 0 0 1 Fault on Warn Force shutdown on warning
User X250 110 50 220 Unload 250psi transducer unload pressure
User Always 10 3 70 Load Delta Differential pressure from unload pressure
User Always 15 0 59 Unload Time Auto mode shut down after unloaded for
this time
User Always 0 0 30 Drain Interval Time between drains (Minutes)
User Always 0 0 10 Drain Time Duration of drain (Seconds)
User Always 0 0 59 Restart Time Auto restart on power up if not 0 (Seconds)
User Always 0 0 10 Wye Delta Wye to delta starter transition time
(Seconds)
User Always 0 0 0 Language French, German, Italian, Spanish, English
User Always 0 0 1 Temp Units Fahrenheit, Celsius
User Always 0 0 2 Press Units Pressure units, Psi, Bar, kPa
Seq Com Mod 0 0 3 Sequence by Disabled,Com, Hours, Remote, Slave,
Time Of Day etc.
Seq Always 0 0 100000 Seq Hrs Used for Hours sequencing mode
Seq Always 1 1 16 Com Number Communications ID number
Seq Always 1 1 16 Machines Number of machines in a system
Seq Always 70 60 185 Low Press Panic start next machine in sequence
Seq Always 10 2 59 Recover Time Keeps multiple machines from starting at
same time (seconds)
Seq Always 0 0 250 Rotate Used to force a machine to stop
Seq Always 0 0 60 Minute Real Time Clock Settings