SECTION 7 TROUBLESHOOTING
153
The unit will not run or
cycles off and on.
Line disconnect switch is
open.
Close the start or
disconnect switch
If the dryer is not operating,
check the disconnect switch or
circuit breaker to be certain it is
on.
Fuse or breaker is open Replace fuse or reset
breaker.
The fuse to the power line
should be checked and
replaced if needed. Never
replace a buRCt fuse with an
oversized fuse.
Faulty refrigerant
compressor or controls.
Determine the cause and
make correction
Failure of compressor to run
may be caused by several
factors. A qualified refrigeration
specialist should check all
electrical and refrigeration
controls, or factory should be
contacted if unit is in warranty.