INSTALLATION, START-UP & MAINTENANCE MANUAL
MODEL NO.: SD-820 / SD-1710
REV 1 – AUGUST 03,.2001
Page 49
SECTION 7
7.3 BACK PRESSURE IS TOO HIGH DURING REGENERATION PHASE
Possible cause Solution
Muffler is blocked
Replace muffler
Outlet check valve failed
Verify springs and bushings on valves
Verify seat o’ring is not damaged
Exhaust valve not fully open
Verify operation of pneumatic actuator
Verify pilot air to actuator
Verify if valve is obstructed
Inlet valve leaks across ports
Remove valve and test for across port
leakage
Install new seals
Inlet valve not fully positioned
Verify the pneumatic actuator for 90°
operation
Verify for leaks across vane of actuator
Pilot air pressure failed due to plugged pilot
filter or damaged pilot line.
Attention!
If you are not able to fix a disturbance, call
S
S
u
u
l
l
l
l
a
a
i
i
r
r
®®
Michigan City Indiana at once. A service technician
will be sent out as soon as possible!
7.4 SHORT-TERM SHUT-DOWN
* Advices
The following sequence is to be heeded when switching off the
adsorption dryer:
Switch off the adsorption dryer when the dryer transfers into repressurization
step, or at any time when both chambers are at full pressure.
Close all the shut off valves up- and downstream of dryer.
Attention!
Dryer will remain pressurized.