32
C. Adjustment of the movable and fixed knife
a) Adjustment of the movable knife-edge and hook stopper
When a movable knife passes the front side of the hook stopper, limit the clearance to be within 0.7~0.8 mm range as the
picture shows. The upper surface of the movable knife-edge should be set up 0.35~0.45mm below the lower side of hook
stopper.
Clearance adjustment of the movable knife-edge and hook stopper front side
Loosen the needle plate and secure the hook stopper on the needle plate
Unfasten the fixing screw of the movable knife shaft eccentric bushing. Insert a thin driver or any adequate size pin into
the hole of the eccentric bushing and turn it to the left and right. The clearance will be adjusted as the position of the
movable knife shaft changes.
After the clearance adjustment, retighten the bushing fixing screw firmly.
[ Fig. 55 ]