Engine staring and stopping mark
Before starting engine
1) Keep pilot valve control lever locked and pilot handle & travel pole neutral. Operator sits on
seat.
2) Turn key switch to ON position, all indicator lights come on except engine hour meter and
LCD module, buzzer tweets, self inspection is finished after 2 seconds and the monitor
system is on normal working condition.
Start engine
1Keep pilot valve control lever locked. 2Turn key switch to ON position.
3Beep horn to warn surrounding people.
4Start engine by turning key switch clockwise to START position. Release key, the
switch will return to ON position.
In order to avoid damage of starter, never operate motor starter for 10 seconds or
more every time. If the engine cant start, turn the key switch to OFF position and
wait at least 2 minutes, then try again. After the wrong start, the engine should be
stopped completely, then you can turn key switch, otherwise it may damage starter.
If there is a flicker in monitor, stop engine at once and check the reason.
FIG. 3-5