48
A2SDV-8C/-12C+/-16C-TLN5F User's Manual
BAR CODE
COM2
DESIGNED IN USA
A2SDV-8C-TLN5F
REV:1.02
JIPMB1
JMD2
JMD1
JTGLED1
JPW1
JPI2C1
JSD1
SRW2
SRW3
SRW4
SRW1
JUIDB
JPL1
1
JWD1
JPG1
JBR1
JPME2
JI2C1
JI2C2
DIMMB1
DIMMB2
DIMMA1
DIMMA2
LED1
1
JD1
JSMB1
JGP1
JBT1
JPH1
JPV1
FANB
JTPM1
JNCSI1
JL1
JRT4
1
JRT3
I-SATA1 I-SATA0
UIDLED1
CM CODE
LEDBMC
eUSB
ON
PWR
JF1
RST X
OH/FF
2
NIC NIC
1 LED
HDD
LED
X
PWR
NMI
ALWAYS POPULATE DIMMx1 FIRST
CPU SLOT6 PCI-E 3.0 X8
CPU SLOT7 PCI-E 3.0 X8
VGA
KEY-M PCIE3/SATA3
KEY-B SATA3/USB3
COM1
LAN1(IPMI_LAN)
LAN5
CPU
USB6(3.0)
USB2/3(3.0)
USB0/1(3.0)
USB 4/5
LAN3
FAN4 FAN3
FAN2 FAN1
LAN4/
LAN2/
FANA
SATA DOM POWER
BT1
JF1
BMC AST2400
JPTG1
JSEL1
1
1. 10G LAN Enable
2. SMBus to PCI-E Slots
2
10Gb LAN Enable/Disable
Use jumper JPTG1 to enable or disable 10G LAN2/3/4/5. Refer to the table below for jumper
settings.
10Gb LAN Enable/Disable
Jumper Settings
Jumper Setting Denition
Pins 1-2 Enabled (Default)
Pins 2-3 Disabled
SMBus to PCI Slots
Jumpers JI
2
C1 and JI
2
C2 allow you to connect the System Management Bus (I
2
C) to the
PCI-E slots. Both jumpers must be set to the same setting (JI
2
C1 controls the clock and JI
2
C2
controls the data). The default setting is Disabled.
SMBus to PCI Slots
Jumper Settings
JI
2
C1 Setting JI
2
C2 Setting Denition
JI
2
C1: Pins 1-2 JI
2
C2: Pins 1-2 Enabled
JI
2
C1: Pins 2-3 JI
2
C2: Pins 2-3 Disabled (Default)