4-42
Supermicro C7Z270-CG Motherboard User’s Manual
GT Extra Turbo Voltage
(Available when GT Voltage Mode is set to Adaptive) Use this feature
to set the extra voltage applied while GT is operating in turbo mode.
Specify a value from 0mV to 2000mV. Enter 0 to use the manufacture
default value.
GT Voltage Override
(Available when GT Voltage Mode is set to Override)
Use this feature to set the Override Voltage applied to the GT domain.
This voltage is specied in millivolts (mV) and uses the BIOS mailbox
MSR 0x150, command 0x11. Specify a value from 0mV to 2000mV.
Enter 0 to use the manufacture default value.
GT Voltage Offset
Use this feature to set the GT Adaptive voltage Target(mV) value from
0mV to 2000mV. Enter 0 to use the manufacture default value.
Offset Prex
Use this feature to set the Offset value as a positive (+) number or
a negative (-) number. The default setting is "+".
GT-UnSliced VR Settings
GT-UnSliced Domain
VR Cong Enable
Select Enable to activate VR conguration options. The options are
Disabled and Enabled.
AC Loadline
AC Loadline is dened in 1/100 mOhms and uses the BIOS mailbox
command 0x2. A value of 100 equals 1.0 mOhm, and 1255 is 12.55
mOhms. Valid range is 0-6249 (0-62.49 mOhms). Enter 0 for AUTO.
DC Loadline
DC Loadline is dened in 1/100 mOhms and uses the BIOS mailbox
command 0x2. A value of 100 equals 1.0 mOhm, and 1255 is 12.55
mOhms. Valid range is 0-6249 (0-62.49 mOhms). Enter 0 for AUTO.
PS Current Threshold1
The PS Current Threshold1 is dened in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals