Supermicro L2/L3 Switches Configuration Guide
59
Syslog logging: enabled(Number of messages 0)
Console logging: disabled(Number of messages 0)
File logging: disabled(Number of messages 0)
Log File Name:
File Max Entries: 500
TimeStamp option: enabled
Trap logging: Critical
Log server IP: None
Facility: local5
Buffered size: 50 Entries
LogBuffer(0 Entries)
LogFile(0 Entries)
1.7.7 MAC Table Logging
Supermicro switches support the logging of MAC address table updates.
Follow the steps below to enable the logging of MAC address table updates.
Step Command Description
Step 1
configure terminal
Enters the configuration mode
.
Step 2
logging mac
-
address
-
table
Enable
s the
logging of MAC address
table updates.
Step 3
end
Exits the configuration mode.
Step 4
show logging
Displays the
Syslog
configuration.
Step 5
write startup
-
config
Optional step
saves this configuration
to be part of the startup configuration.
The
no
logging mac
-
address
-
table
command
disables
the l
ogging of MAC
a
ddress table
updates.
The example below shows the commands used to enable the logging of MAC address table updates.
SMIS# configure terminal
SMIS(config)# logging mac-address-table
SMIS(config)# end
1.7.8 Trap
Supermicro switches provide an option for specifying the type of traps that are to be logged.